[AMBER] ATTN GLYCAM users: CY atom type work around

From: Jodi Ann Hadden <jodih.uga.edu>
Date: Sat, 10 Dec 2011 00:50:07 +0000

Currently there is an issue with the CY atom type which overlaps in ff99SB and GLYCAM.

This issue is in the process of being resolved, but in the mean time, please use the following work around to ensure your prmtops contain the correct information and your ring geometries are not distorted when building a sugar that contains a CY atom (e.g. sialic acid, 0SA).

- Go to www.glycam.org/params and download the most up-to-date version of the parameters.
- If you are building a system that contains only a protein, load only ff99SB into leap, do not load GLYCAM.
- If you are building a system that contains a carbohydrate, load GLYCAM, ff99SB, then GLYCAM again.

source leaprc.GLYCAM_06
source leaprc.ff99SB
source leaprc.GLYCAM_06

This should ensure your input files contain correct information.



_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Dec 09 2011 - 17:00:02 PST