Hi Brian,

As you mentioned, yes, the coordinates are shifted for the QM calculation. In fact, the QM zone is put in the center of the box and the whole system is wrapped around it, but that only happens for the QM calculation, without changing the actual coordinates.

As to what is happening, it would be helpful to see your input and output files. Also, it may be a good idea to run the calculation printing the coordinates at every step to follow your system. There is also an option (can't recall now, but it is in the manual) that tells sander to print the QM zone as a PDB file at every step. My guess is that somehow sander is including in the QM zone some atom(s) that should not be there.

Good luck,
Gustavo.
--
Sent from my iPad.
On 07/09/2011, at 18:37, Brian Radak <radak004.umn.edu> wrote:
> I am running many QM/MM NVT simulations of small organic molecules (QM) in
> water (MM) using rhombic dodecahedral PBCs.  The starting structures come
> from 1 ns NpT MM equilibrations with the volume reset to a rounded value
> (these are for TI calculations and I thought it sensible and not
> unreasonable to set the volume constant amongst all lambda values, the
> change is usually less than 0.5%).  Sometimes, but not always, sander bombs
> out with the following error, either after many steps of QM/MM MD or
> sometimes after no steps at all:
> 
> ****************************************************
>  ERROR: QM region + cutoff larger than box dimension:
>  QM-MM Cutoff =  10.0000
>  Coord   Lower     Upper    Size    Radius of largest sphere inside unit
> cell
>     X   -11.486    11.276    22.762    12.092
>     Y   -12.143    12.058    24.200    12.092
>     Z   -11.619    11.293    22.911    12.092
>  ****************************************************
> SANDER BOMB in subroutine QM_CHECK_PERIODIC<qm_mm.f>
> QM region + cutoff larger than box
> cannot continue, need larger box.
> 
> As a specific example this happens to isopropanol (generously ~6 A wide) in
> a 34 A RHDO.  I don't think I am wrong in concluding that there is easily 12
> A (qm_cut + skinnb) to the nearest RHDO face.  In any event I got no such
> error during the MM simulation.
> 
> I looked in the code and I don't fully understand how the table of values is
> arrived at.  It would seem that the system is shifted by the geometric
> center of mass of the QM region (which is why "Lower" is negative and
> "Upper" is positive?), but I'm not exactly sure what the reason for this is
> (I'm sure it's a very good one, I just don't know what it is).  Anyway,
> somewhere in that shifting, the molecule seems to get split across a
> periodic wall and thus the "size" of the molecule is calculated
> erroneously.  There is also a comment in the code that something bad (this?)
> would happen if the QM region diffuses extensively.
> 
> Can anyone explain what's going on here?  Has anyone seen this problem
> before?  I'm willing to give fixing this a try, but I think I need a little
> bit broader vision of the code as this extends across sqm, the image code,
> and the ewald code.
> 
> Thanks!
> Brian
> 
> P.S. On a related note, 12.092 A seems too small for the largest sphere in
> the "familiar" form of a RHDO.  Is this a consequence of the triclinic form
> used in the simulation?
> 
> -- 
> ================================ Current Address =======================
> Brian Radak                                             :     BioMaPS
> Institute for Quantitative Biology
> PhD candidate - York Research Group       :     Rutgers, The State
> University of New Jersey
> University of Minnesota - Twin Cities         :     Wright-Rieman Hall 101
> Graduate Program in Chemical Physics     :     610 Taylor Road,
> Department of Chemistry                          :     Piscataway, NJ
> 08854-8066
> radak004.umn.edu                                 :
> radakb.biomaps.rutgers.edu
> ====================================================================
> Sorry for the multiple e-mail addresses, just use the institute appropriate
> address.
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Sep 07 2011 - 17:30:02 PDT
Custom Search