Re: [AMBER] TR: Antechamber trouble with COA-acyl chain

From: Adrian Roitberg <roitberg.qtp.ufl.edu>
Date: Wed, 13 Jul 2011 19:47:21 +0200

the message "QMMM: System specified with odd number of electrons ( 311)
QMMM: but odd spin ( 1). You most likely have the charge of
QMMM: QM region (qmcharge) set incorrectly. Correct error and re-run
calculation" seems reasonably clear to me.

Are you sure that you specified the correct total charge for your system
in the antechamber input ? sqm disagrees with your choice...