Re: [AMBER] Problem in the energetics of the system Shake cannot be accomplished.

From: Daniel Roe <daniel.r.roe.gmail.com>
Date: Wed, 29 Jun 2011 11:45:13 -0400

Hi,

This kind of error usually arises because your system has not been
properly minimized. In particular, systems with explicit solvent
require careful minimization and equilibration. If you post the
minimization/equilibration procedure you have used to this point we
may be able to make some recommendations.

-Dan

On Wed, Jun 29, 2011 at 11:06 AM, hari krishna <haricoolguy111.gmail.com> wrote:
> Dear All:
>
> I am doing the MD simulation of the protein and RNA complex strucutre in the
> presence of solvent. There is nothing wrong in the charge of the system, its
> neutral only. But while heating the system its shows the following error
> that shake cannot be accomplished and deeper problem in the energetics of
> the system.
>
> I have used force field 99 and tried with force field 03 it shows the same
> error. there is no modified force field applied to any of the system.
>
>
> NITER, NIT, LL, I and J are :    0    0  636 9565 9564
>
>
> What shall i do now
>
>
> S.Harikrishna
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jun 29 2011 - 09:00:03 PDT