On Fri, Jan 21, 2011, Ganesh Kamath wrote:
>
> I used NAMD to run a box of 901 molecules of water using TIP3P model. I used
> tleap to generate a tip.top for 901 molecules
> and using TIP3P model. I tried using ptraj to read the namd file using the
> tip.top as parm file to compute the diffusion coefficient of
> water at 298 K I get 3.01*10-5 cm2/sec. which is incorrect.
Was any thermostat or barostat used for the NAMD simulation? That would
make the simulation suspect for calculating time-dependent properties.
Also, were the snapshots in namd indeed saved at 1 ps intervals?
...regards...dac