Re: [AMBER] error in atomic charge calculation in RED server

From: FyD <fyd.q4md-forcefieldtools.org>
Date: Tue, 12 Oct 2010 09:30:37 +0200

Chinh Su,

> I saw all the example files with around 25
> atoms, is it the maximum number of atoms I should limit for each submitted
> input file?

When you want to derive RESP charges, you could have two main limits:
- that in the QM program;
as you use Gaussian see http://www.gaussian.com/g_tech/g_ur/b_proglimits.htm
- that used in the fitting step.
We use an adapted RESP version by now (see
http://q4md-forcefieldtools.org/RED/resp/) and the boundaries (number
of constraints, no molecules etc..) for the fit have been pushed back.

Around 100 atoms for this type of complex is acceptable - when you use
HF or DFT; at least on our hardware ;-)

regards, Francois



_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Oct 12 2010 - 01:00:06 PDT