Dear NAB and 3D-RISM Developers,
I would like to run some simulation in NAB of AmberTools with 3D-RISM
and i have some questions (in addition to my previous message):
1.
What is the "tolerance" statement (like:
mm_options("tolerance=1e-11");)? In manual it is written that this is
residual, but how actually it is calculated: is it a L2 norm for the 3D
total correlation functions h (or maybe c or gamma):
tolerance = (\sum_{number of 3D functions} [ \int_{V} (h_new -
h_old) dV ] ) / {number of 3D functions}
where h_new and h_old - 3D arrays functions of two subsequent
iterations.?
2.
If i gave a right definition of the "tolerance", why the proposed value
for minimization (and i suppose for one point calculation) with
3D-RISM is so small 10-11? I suppose that the accuracy 10-5 is more
the enough if we want to calculate chemical potential out of total
correlation functions.
Are there some obstacles that i do not see so far?
And what is an appropriate value of "tolerance" to use for 1 point
calculation of chemical potential without wasting too much of computer
resources?
I would be very pleased if you know something about the questions and
drop me a message.
Thank you very much.
Andrey Frolov, PhD student at Max Planck Institute for Mathematics in
the Sciences, Germany