[AMBER] PMEMD10 - energy summation bug?

From: Mag. Thomas Taylor <thomas.taylor.univie.ac.at>
Date: Thu, 21 Jan 2010 13:32:19 +0100

Hello Amber Devs!

Please find below the energy output from nearly identical forcefields (the one
for sander misses all the special charmm/chamber flags) using the same
coordinates.

EPtot is 37075.6031 in both cases, but I believe this incorrect for PMEMD10,
because here an additional term (IMP > 0) should be added. One can see that
DIHED is different for the two outputs, so I guess the IMP energy term is
missing when summing all energy terms for EPtot.


AMBER10 (SANDER10 - hacked CHAMBER converted forcefield)

 NSTEP = 0 TIME(PS) = 0.000 TEMP(K) = 299.21 PRESS =
0.0
 Etot = 61156.7558 EKtot = 24081.1527 EPtot =
37075.6031
 BOND = 450.8583 ANGLE = 9008.8580 DIHED =
4102.0287
 1-4 NB = 2276.6115 1-4 EEL = 113363.7474 VDWAALS =
-9065.8493
 EELEC = -83060.6515 EHBOND = 0.0000 RESTRAINT =
0.0000
 Ewald error estimate: 0.1592E-04


AMBER 10 (PMEMD10 - CHAMBER converted forcefield)

 NSTEP = 0 TIME(PS) = 0.000 TEMP(K) = 299.95 PRESS =
0.0
 Etot = 61216.1362 EKtot = 24140.5331 EPtot =
37075.6031
 BOND = 450.8583 ANGLE = 9008.8580 DIHED =
4069.9719
 UB = 0.0000 IMP = 32.0568 CMAP =
0.0000
 1-4 NB = 2276.6115 1-4 EEL = 113363.7474 VDWAALS =
-9065.8493
 EELEC = -83060.6515 EHBOND = 0.0000 RESTRAINT =
0.0000
 Ewald error estimate: 0.1592E-04

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber