[AMBER] error of cutoff list exceeds largest sphere in unit cell

From: <sangita.imtech.res.in>
Date: Wed, 20 Jan 2010 14:41:39 +0530 (IST)

Hello

I am simulating cubic water box(TIP3BOX) using amber9 and getting the following
problem.
 After 31800 step in second molecular dynamics

 Cutoff list exceeds largest sphere in unit cell!!
 Big problems with imaging!!
 a,b,c = 30.4619278953131 27.9998611680012
   30.4338994135927
 alpha,beta,gamma = 90.0000000000000 90.0000000000000
   90.0000000000000
 cutlist,sphere = 14.0000000000000 13.9999305840002

I am using the following namelist:

First i am relaxing the box :
imin=1,maxcyc=5000,ntb=1,cut=12

Moleculat dynamics 1
imin=0,nstlim=20000,dt=.001,ntpr=200,ntwx=200,
ntx=1,ntt=3,gamma_ln=1,cut=12,ntb=1,tempi=0,temp0=300

Molecular dynamics 2
imin=0, nstlim=50000,dt=.001,irest=1,ntpr=200,ntwx=200,
ntx=7,ntt=3,gamma_ln=1,ntb=2,ntp=1,pres0=1,taup=2.0,cut=12,tempi=300,temp0=300

If anybody can shortout my problem then help me.
Thanks
Sangita Kachhap