Jianping,
> But I only can run this minimization 6 steps.
In that case I suggest looking at the parameterization of the
atom indicated by GMAX in the output - vdw and bonds, angles,
dihedrals involving that atom. Particularly the vdw of the atom;
also its charge.
suggest Also checking your structure in that neighborhood for artifacts.
Bill
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber