Re: [AMBER] unexplained blow-up at restart

From: Sally Pias <sallypias.gmail.com>
Date: Mon, 13 Jul 2009 08:01:29 +0100

For the record, setting nscm to 0 did not solve the problem of
extremely high restraint energy on restart (though I do think keeping
nscm at 0 with positional restraints is probably important). I was
able to restart successfully by using the end coordinates of the
previous run as the reference coordinates, rather than the coordinates
of the structure prior to MD. I found the following reflector
discussion helpful in this regard:
http://archive.ambermd.org/200703/0071.html (subject line:
"coordinate changes using ptraj").


On Fri, Jul 10, 2009 at 12:59 PM, Sally Pias<sallypias.gmail.com> wrote:
> Carlos,
>
> It sounds like you may have identified the problem, as the only thing
> I noticed in visualizing the md2_NPT trajectory is that the molecule
> shifts over (translates) noticeably at step 1.  That is why I tried
> the Langevin thermostat, as I thought it might be a "flying ice cube"
> effect.  I will try setting ntcm to 0.
>
> Many thanks,
>
> Sally
>
>
> On Fri, Jul 10, 2009 at 11:58 AM, Carlos
> Simmerling<carlos.simmerling.gmail.com> wrote:
>> Sally- I got your files.
>> can you redo rune after changing ntcm to 0, and also try switching back to
>> Berendsen thermostat (ntt=1)?
>> try them separately. it may be that in run2 the molecule was recentered, and
>> the refc was not. in general combining positional restraints with removal of
>> center of mass motion can be dangerous. we have better checks in more recent
>> versions of Amber
>> carlos
>

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Jul 13 2009 - 01:09:25 PDT