On Thu, 2009-05-07 at 10:09 -0400, David A. Case wrote:
> On Thu, May 07, 2009, Carlos Simmerling wrote:
>
> > I worry that you get a "parm file in amber 7" message- that's pretty old.
>
> Believe it or not, we introduced the "new" prmtop format way back in Amber 7.
> So, when VMD says "parm7", it means "parm7 or later", as opposed to the "old",
> Amber6-and-earlier, prmtop format.
>
> > the HW-HW are likely water.
>
> I agree, and these may be treated specially in NAMD. But I'm hoping there are
> NAMD users on the list who will know for sure what is going on.
>
>From memory, NAMD treats TIP3P-like water differently to Amber.
Amber uses three bonds (with Shake to constraint all the distances, 2 x
OW-HW and one HW-HW)
NAMD, by default, uses the HW-OW-HW bond angle and the 2 OW-HW distances
to do the same thing.
There was a way to force Amber-like behavior, but I can't remember what
it was off the top of my head. There should be instructions in the NAMD
documentation, try looking for 'use of Amber force field'
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed May 20 2009 - 15:03:44 PDT