On Tue, Apr 07, 2009, Helena P M Tossavainen wrote:
>
> After a successful simulated annealing run I obtain the list of NMR
> restraint violations, made by the LISTOUT=POUT command. However, the lines
> "RMS deviation from ideal bonds/angles" are missing.
Are you running a parallel simulation? The RMS deviations mentioned
above are only printed for a serial simulation (since we never actually
communicate the needed information to all nodes in parallel.) I
generally run a final, one step, serial minimization at the end to get
these statistics.
...dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Apr 08 2009 - 01:16:29 PDT