Re: [AMBER] fillratio error in mmpbsa

From: Han Ming <minghan2000.gmail.com>
Date: Wed, 1 Apr 2009 16:06:08 +0100

I used mm-pbsa in amber9. My experience to fix this problem is to change the
pbsa_lig.in file manually after the file is produced immediately, that is,
should change the fillratio parameter before ligand calculation. You can try
it. Good luck. Ming

On Wed, Apr 1, 2009 at 7:42 PM, m m <m-22.hotmail.fr> wrote:

>
> Hi,
>
> i run mmpbsa calculation with amber10, i have no probleme with extrat
> coordodinate, but with binding energy
> the calculation stop with this message error:
> sander -O -i pbsa_lig.in -o pbsa_lig.155.out -c ./snapshot_lig.crd.155 -p
> ./mmR18.prmtp not successful
> In pbsa_lig.155.out i found: PB Bomb in setgrd(): focusing grid too
> large 2
> reset fillratio to a larger number
> 2.000
> when i add fillratio=4 to pbsa_lig.in, ans i do just: sander -O -i
> pbsa_lig.in -o pbsa_lig.155.out -c ./snapshot_lig.crd.155 -p ./mmR18.prmtp
> not successful, i obtain a good pbsa_lig.155.out.
> what can i do to resolve this problem?
> Thanks
>
> _________________________________________________________________
> Découvrez toutes les possibilités de communication avec vos proches
>
> http://www.microsoft.com/windows/windowslive/default.aspx_______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber