On Thu, Oct 23, 2008, Sally Pias wrote:
> I have been
> unable to maintain constant temperature (at 300 K) upon switching from
> ntt=3 to ntt=0. In previous simulations, the temperature increased
> gradually from 298 K (after an initial dip) to 310 K over 30
> nanoseconds.
This is excessive heating, but it is hard to know the cause without knowing
what input parameters you used. Good energy conservation with ntt=0 generally
requires setting dt=0.001, tol=0.0000005 (or thereabouts), and
dsum_tol=0.000001. There may be other problems as well that can lead to
significant heating, especially if the conformation of the system is changing
during the simulation.
...good luck...dac
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
to majordomo.scripps.edu
Received on Thu Oct 23 2008 - 23:45:38 PDT