Re: AMBER: Temperature regulation

From: Carlos Simmerling <carlos.simmerling.gmail.com>
Date: Mon, 15 Sep 2008 21:07:57 -0400

I don't see anything that would obviously cause trouble in the
thermostat. using ntt=1 without setting the coupling constant may not
give tight control, though, depending on the default in your amber
version (see below).
ntr=1 won't work without additional info that you don't seem to have.
ntb=0 and igb=0 give you a combination that you need to think about
carefully, especially without anything in your &ewald namelist.
also- which amber version are you using? dtemp has been retired since
amber9 (see the manual).
is there a difference between average temperature in the previous run
and the current one? keep in mind that instantaneous T fluctuates, so
you need to look at averages.
maybe if you show us some of the output it will be more clear what's going on.
carlos

On Mon, Sep 15, 2008 at 8:48 PM, julliane Yoneda
<jullianeyoneda.yahoo.com.br> wrote:
> Dear AMBER users,
>
> I am running a restrained molecular dynamics simulation in vacuum with the
> following input:
>
> &cntrl
> imin = 0, irest= 1, ntpr= 50, ntf=2,
> ntwx =100, ntb = 0, ntx = 5, ntc = 2, nsnb=10,
> nstlim = 100000, cut = 9.0, igb = 0, ntr=1,
> t = 30.0, dt =0.002,
> tempi = 300.0, temp0 = 300.0, ntt = 1, dtemp=4.,
> /
> &ewald
> /
>
> I divided the simulation in 10 parts using the same input. Everything seems
> to be ok in the output.
> The problem is that every time the simulation is restarted the temperature
> oscillates to 240 K… I tried to use ntt=4 but is seems to be worst because
> the temperature goes to 150K… I don't understand what is happening…
> Could someone help me, please?
> Thank you very much;
> Julliane Yoneda
>
> ________________________________
> Novos endereços, o Yahoo! que você conhece. Crie um email novo com a sua
> cara .ymail.com ou .rocketmail.com.



-- 
===================================================================
Carlos L. Simmerling, Ph.D.
Professor, Department of Chemistry
CMM Bldg, Room G80 Phone: (631) 632-1336 Fax: 632-1555
Stony Brook University E-mail: carlos.simmerling.gmail.com
Stony Brook, NY 11794-5115 Web: http://comp.chem.sunysb.edu
===================================================================
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
      to majordomo.scripps.edu
Received on Wed Sep 17 2008 - 03:09:00 PDT