Dear AMBER users,
 
I am running a restrained molecular dynamics simulation in vacuum with the following input:
 
&cntrl
imin = 0, irest= 1, ntpr= 50, ntf=2,
ntwx =100, ntb = 0, ntx = 5, ntc = 2, nsnb=10,
nstlim = 100000, cut = 9.0, igb = 0, ntr=1,
t = 30.0, dt =0.002,
tempi = 300.0, temp0 = 300.0, ntt = 1, dtemp=4.,
/
&ewald
/
 
I divided the simulation in 10 parts using the same input. Everything seems to be ok in the output.
The problem is that every time the simulation is restarted the temperature oscillates to 240 K… I tried to use ntt=4 but is seems to be worst because the temperature goes to 150K… I don’t understand what is happening…
Could someone help me, please?
Thank you very much;
                                                 Julliane Yoneda
  Novos endereços, o Yahoo! que você conhece. Crie um email novo com a sua cara .ymail.com ou .rocketmail.com. http://br.new.mail.yahoo.com/addresses
-----------------------------------------------------------------------