Re: AMBER: Antechamber, net molecular charge

From: Junmei Wang <junmwang.gmail.com>
Date: Mon, 10 Mar 2008 09:39:08 -0500

The program tries it best to read/calculate the charge information directly
from the input. However, not all the input formats provide the charge
information: gout, mopout, etc. explicitly have the net charge information;
the partial charges in mol2 format can be used to calculate the net charge;
while pdb format does not have charge information at all. Therefore, net
charge must be read in just for some formats. By the way, the net charge
specified by the -nc flag always override the read/calculate one.

Best

Junmei


On Sun, Mar 9, 2008 at 11:51 PM, gurpreet singh <gps.iitm.gmail.com> wrote:

> Respected users
>
> I am using version 9.0 of AMBER. My question is regarding the prep file
> generation using antechamber module in AMBER.
>
> How important is to use the option of (nc) net molecular charge ( in case
> of charge molecules) while using the command of antechamber to obtain the
> prepi file.
>
> I tried the same command with and without mentioning the net molecular
> charge option but did not find any difference in the two prep files.
>
> So where that difference will come? or lets say if I did not mention that
> option, is that a problem?
>
>
>
> Thanks
>
>
> Regards
> Gurpreet
>

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Mar 12 2008 - 06:07:22 PDT
Custom Search