Hi,
I am using Amber 9. Do I need to add ions to the charged ligand file? But in
that case, the number of atoms in the complex and the ligand will not match
and the pbsa calculation will stop. How do I perform pbsa calculations for
charges ligands?
Your help is appreciated.
Regards,
Neha
On 8/19/07, Ray Luo <rluo.uci.edu> wrote:
>
> Are you using Amber8? Have you patched all bugfixes for it?
> Best,
> Ray
>
> On Aug 18, 2007, at 10:20 PM, Neha Gandhi wrote:
>
> Hi,
>
> I have been performing pbsa calculations for charge ligands like
> glycosaminoglycans. But I the PBTOTAL is high negative (-1000 Kcal/mol)
> which is not accurate. I used the internal pbsa electrostatic potential
> calculator in amber 9 rather than external programs like delphi. Is it
> possible that internal pbsa will not work for charged ligands according to
> this tutorial.
> http://www.teokem.lu.se/~ulf/Methods/mm_pbsa.html<http://www.teokem.lu.se/%7Eulf/Methods/mm_pbsa.html>
>
> Do I need external program or there is something wrong with my
> calculations?
>
> Kindly advice.
> Cheers,
> Neha
> Curtin university of technology
>
>
>
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Aug 22 2007 - 06:07:14 PDT