Hi Professor Case,
Thanks for your response.
Yes, I really do have a 3 component system : multiple peptides (on the
order of 20), multiple organic solvent molecules (glycerol, which i
created in antechamber with gaff), and multiple waters.
I suppose I could make a pdb file with the correct ratio of glycerols
to peptides, replicate that manually/periodically enough times to get
the system size I want, then solvateBox to add the water. I was
wondering if there was an easier way that didn't involve manual placing
of all the peptides and organic molecules before solvating with water.
-Nick
On Jun 26, 2007, at 8:08 AM, David A. Case wrote:
> On Thu, Jun 21, 2007, Nicolas Lux Fawzi wrote:
>
>> Could someone point me to a tutorial or any other info regarding
>> setting up simulation system consisting of:
>> multiple copies of short caped amino acids (ACE-X-NME) [ how do I get
>> multiple copies of peptide in a system?
>
>> multiple copies of a GAFF/antechamber-built organic co-solvent built
>> from a single pdb file
>
> The most straightforward approach would be to have a pdb file with
> multiple
> copies of the organic molecule, and then use the solvateBox or
> solvateOct
> commands to add the water. But maybe I don't understand your question:
> do you really have three components: some peptides, an (unspecified)
> organic
> solvent, and water?
>
> ....dac
>
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber.scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu