On Sat, May 12, 2007, Catein Catherine wrote:
>
> I am interest to do the distance restraint for two groups of atoms using
> their center of mass. It is the way I set the distance.restraint file.
> However, it did not work properly.
It would be more helpful if, instead of just saying "it did not work
properly", you said exactly what sort of result to obtained.
>
> # distance restrainst for group 1 (atom 122-150) and group 2 (atom 151 to
> 169)
>
> &rst iat=1,2, r1=0.0, r2=5.0, r3=5.0, r4=50.0, rk2 =30.0, rk3 = 30.,
> igr1(122/150), igr2(151/169), ir6=0 /
This is illegal syntax in the namelist command. "igr1" and "igr2" are arrays,
that have to be filled in, probably like this:
igr2 = 151,152,153,154,155,156,157,158,159,160,161,
162,163,164,165,166,167,168,169,0
I don't think the "0" is required at the end, but it might be safer to put it
there.
...good luck...dac
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun May 13 2007 - 06:07:48 PDT