Is there a molecular weight limitation in antechamber? I have been
trying to load a series of penicillins into antechamber. The molecules
with small side chains work just fine, but as the side chains increase
in size I get an antechamber message that says:
For atom [11]:O the best APS is not aero, exit
1) Double check the structure (the connectivity) and/or
2) Adjust atom valence penalty parameters in APS.DAT, and/or
3) Increase MAXVASTATE in define.h and recompile bondtype.C
4) Increase PSCUTOFF in define.h and recompile bondtype.C
I have verified that the structures and connectivities are correct.
This seems to occur when the number of electrons in the system exceeds
200.
Can someone suggest a workaround for this?
John Beale
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu