AMBER: Antechamber RESP charges do not sum to zero even with -nc 0 flag

From: Bob Johnson <robertjo.physics.upenn.edu>
Date: Fri, 07 Jul 2006 10:55:32 -0400

Hello everyone,
I am trying to generate a force field for trimethylamine. I have optimized the
geometry and obtained the charges using Gaussian 03. I then execute the
following command to assign RESP charges using antechamber:
antechamber -i tma-resp.log -fi gout -o tma.prepin -fo prepi -c resp -nc 0

The assigned charges are reasonable except that the total charge of the molecule
is 0.004e. It seems that if antechamber kept 4 decimal places, the assigned
charges would be closer to zero. Any ideas how to fix this?
Thanks,
Bob Johnson
PhD Student
Department of Physics & Astronomy
University of Pennsylvania
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Jul 09 2006 - 06:07:21 PDT