RE: AMBER: problem in minimization

From: Ross Walker <ross.rosswalker.co.uk>
Date: Wed, 1 Jun 2005 09:56:46 -0700

Dear Anand,

> i am trying to minimize the cluster struture of
> organic molecules containing 64 molecules, but the energy minimizing
> ended with the following error..could anyone inform the
> reason for this
> error..

> Here is the input file:
> min (no shake, periodic) - just enough to relax for md,
> system:PIMB-monomer
> &cntrl
> imin = 1, igb = 0, maxcyc = 1000000,
> ntc = 1, ntf = 1, ntb=0, nsnb = 999,
> cut = 4.0, scee = 1.2,
> &end

A few comments here:

1) Maxcyc = 1000000 -> This is a very large number of minimisation steps to
be running, do you intend to get to a very good minimum or are you just
cleaning things up prior to MD? In the latter case maxcyc of 500 or so is
plenty.

2) nsnb = 999 -> Is there a reason for changing this from the default of 25?

3) cut = 4.0 -> This way way way too short a cut off. For periodic
boundaries the minimum should be 8.0A but for gas phase and implicit solvent
it needs to be much bigger, say 16 angstroms or more. While this will make
your simulation very slow it is essential to get reasonable results. You
cannot hope to get meaningful results with a cutoff of only 4 angstroms.
Getting the wrong answer quickly is not a good idea.
          
> | Flags: ISTAR2 MPI

You don't state how big your system is but ISTAR2 limits you to 2^15 atoms =
32768.
You may want to recompile with ISTAR4 if your system is larger than this.

> | NONPERIODIC ntb=0 and igb=0: Setting up nonperiodic simulation
> Ewald PARAMETER RANGE CHECKING:
> parameter nfft1: (grid size) has value 432
> This is outside the legal range
> Lower limit: 6 Upper limit: 256
> Check ew_legal.h

This is suggesting that the virtual box that sander creates around your
system is 432-extraboxdim(60 anstroms) = 372 angstroms in the x direction.
At this the y and z directions have not even been checked. Is your system
really this big? It suggests to me that you have a problem in your inpcrd
file - perhaps you have an atom a long way away? Try creating a pdb from
this inpcrd file and looking at it. Alternatively your inpcrd file may be
corrupted in some way. Please check your input. If you really have a system
this big and it is something really worth looking into then please get back
to me and we will discuss options.

All the best
Ross

/\
\/
|\oss Walker

| Department of Molecular Biology TPC15 |
| The Scripps Research Institute |
| Tel:- +1 858 784 8889 | EMail:- ross.rosswalker.co.uk |
| http://www.rosswalker.co.uk/ | PGP Key available on request |

Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.



-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Jun 01 2005 - 18:53:00 PDT