Re: AMBER: about run time in GB and PB

From: Phineus Markwick <markwick.embl-heidelberg.de>
Date: Thu, 21 Apr 2005 10:26:26 +0200

Dear Yong Xu,

what are the cut-off values in your two simulations? The default cut-off
for simulation in explicit water
is 8 angstrom, whereas for GB one should make the cut-off considerably
larger (ideally as large as the system itself).
Of course, using a large cut-off with the GB simulation will
considerably slow down the calculation....

regards,
Phin.

Yong Xu wrote:

>Dear all
>
>I found that on my computer, time used for running GB_MD with com.pdb (protein+ligand = 2700 atoms) is almost same as the time used for running PB_MD with com_water.pdb (protein + ligand + water = 34000 atoms)
>is this phenomenon normal?
>
>
>Best regard!
>
>Yong Xu
>yxu.mail.sioc.ac.cn
>2005-04-21
>
>===========================================================
>* Yong Xu
>* State Key Lab of Bioorganic & Natural Product Chemistry
>* Shanghai Institute of Organic Chemistry
>* Chinese Academy of Science
>
>* 354 Feng Lin Road, Xu Hui District
>* Shanghai, 200032, China
>
>* Email: yxu.mail.sioc.ac.cn
>* xuyongch.yahoo.com
>===========================================================
>
>
>
>-----------------------------------------------------------------------
>The AMBER Mail Reflector
>To post, send mail to amber.scripps.edu
>To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
>
>


-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Thu Apr 21 2005 - 09:53:01 PDT