> I would like to determine RESP charges with a multiple-conformation
> charge-fitting scheme. First limitation is the 500-charge centre.
Modify the source & recompile. We did it for a huge number of
restraints/molecules etc... RESP needs to be modified & recomplied
See $AMBERHOME/src/resp/resp.f
parameter (maxq = 2000)
parameter (maxlgr = 200)
parameter (maxmol = 100)
> Second,
> is the format for reading charge restrains (two rows per atom in the
> molecules).
> The fitting works for up to seven molecules.
No it works for more than 8: you have to use a new line in this case...
Use RED-I with 10 orientations and you will get it. I can also send you the
un-official RED-II web site for multi-conformation & multiorientation RESP fit
if you wish...
[...]
> Would be glad to know how to make RESP read more than two rows per atoms.
Please use RED-I or better RED-II and all is done automatically.
Regards, Francois
--
F.-Y. Dupradeau
DMAG EA 3901 & Faculte de Pharmacie, Amiens, France
The Scripps Research Institute, La Jolla, CA, USA
--
http://www.u-picardie.fr/labo/lbpd/FyD.htm
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Tue Apr 19 2005 - 06:53:00 PDT