AMBER: single-stranded poly(rC) simulation

From: Kateryna Miroshnychenko <kateryna_mirosh.ire.kharkov.ua>
Date: Mon, 4 Apr 2005 16:49:39 +0300

Dear AMBER users,

I've modelled single-stranded poly(rC) with explicit water and
counterions starting from its helical conformation. But after 2.1 ns
 production simulation my poly(rC) seems to be gone quite far from its
 initial helical conformation (first snapshot). Backbone RMSD is
 around 3 A (see attachment)).

 The simulation protocol, I've used, is similar to that from the DNA
 tutorial:
 minimization of solvent and of the all system
 20 ps heating from 0 to 300 with weak positional restraints on polyrC
 200ps equilibration md
 2.1 ns production run
 
How do you think, may be there is a problem in my simulation protocol
or such simulations are quite normal for single-stranded oligonucleotides?
How can I estimate he helicity of the distorted polyrC?
I'm new to AMBER so any suggestions of more experienced users would be
helpful.

With many thanks in advance,
 Kat
mailto:kateryna_mirosh.ire.kharkov.ua

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu

Received on Mon Apr 04 2005 - 15:53:01 PDT
Custom Search