On Wed, Mar 30, 2005, S.Sundar Raman wrote:
> i read the biotin streptavadin tutorial.
> i would like to know how you gave value for cap command.
> how to calucluate that regions position.
> when satrted to minimise it, it says ewald parameter are exceeded the
> limits.how can i solve this problem
In modern versions of Amber, the default value of ntb is 1, indicating a
periodic simulation. You need to set this to zero for a cap simulation.
I will update the tutorial file, which came from an earlier version of the
code.
....thanks for the report...dac
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Thu Mar 31 2005 - 16:53:01 PST