Dear Dr Duke,
Thanks for your answer.
Actually I have at the end of the simulation my DUMPAVE file and the
file fort.35 which are
perfectly identical.
Yours sincerely,
Fabien
> Fabien -
> As far as nmropt = 1 stuff goes, pmemd basically does pretty much the
> exact same things as sander 6/7. I believe there are some new input
> formats supported by sander 8 for restraints/frozen atoms, and this
> stuff is not supported by pmemd (you have to use the amber 6/7 GROUP
> input), but you are not doing this sort of thing here. So the pmemd
> nmr code is really just a port of sander code to f90, whith nmropt > 1
> features stripped out. I did not otherwise touch the stuff because it
> is convoluted, not particularly well documented, and there is not a
> complete set of regression tests. I am saying all this basically to
> put the question back in the sander court. As far as any analysis I
> can do, I have tracked through the code and it looks like a temporary
> file is being opened on unit 35; I presume the file is a temporary
> because a name was not provided, but it also looks like this file
> should be the dumpave file. Do you otherwise get the dumpave file you
> provided a name for? Anyway, whoever wrote this stuff should respond
> to this message, and the amber group should specify what is going on
> here in the doc, rewrite the code, or whatever.
> Regards - Bob Duke
>
--
__________________________________________________________________
Fabien Cailliez Tel : 01 58 41 51 63
Laboratoire de Biochimie Théorique e-mail : cailliez.ibpc.fr
IBPC 13, rue Pierre et Marie Curie
75005 Paris
__________________________________________________________________
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Mon Jan 17 2005 - 16:53:01 PST