Re: AMBER: single strand simulation

From: Thomas E. Cheatham, III <cheatham.chpc.utah.edu>
Date: Tue, 9 Nov 2004 17:32:58 -0700 (Mountain Standard Time)

> I'm using Amber7 to do a MD simulation of a single strand DNA with a
> modified base in explicit water. The protocol is same as DNA tutorial on
> Amber website, except using ntt=1 for temperature control. But the
> simulation got error termination with vlimit and shake problem. Any
> suggestion is appreciated.

> NITER, NIT, LL, I and J are : 0 2 74 240 241

Are atoms 240 and 241 in the modified base? Make sure that your modified
base parameters is not adding a significantly higher frequency (larger
force constant) bond interaction. Otherwise, make sure that the system
was minimized prior to performing MD (without restraints). SHAKE and VMAX
failures are usually evidence of a hot spot. This could be due to a bad
geometry leading to large forces and much motion or force constants that
are too high leading to vibrations too fast for the integrator to
integrate...

Good luck.



-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Nov 10 2004 - 00:53:00 PST