Re: AMBER: Temperature in Nmode

From: ML <lepsik.uochb.cas.cz>
Date: Tue, 10 Feb 2004 21:46:19 +0100

Dear Dr. Case,
what a beauty in simplicity! Thank you very much!

It definitely SHOULD go to the manual!

Regards,

       Martin



David A. Case wrote:

>On Tue, Feb 10, 2004, ML wrote:
>
>
>
>>I found that default temperature for nmode is 298.15. How do I change
>>this to 300K?
>>
>>
>>
>
>You can set the variable "t" in the &data input to the temperature you
>want. (Somehow, this never made it into the manual.)
>
>...regards...dac
>-----------------------------------------------------------------------
>The AMBER Mail Reflector
>To post, send mail to amber.scripps.edu
>To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
>
>
>

-- 
-----------
Martin Lepsik
Dept. of Molecular Modeling
Institute of Organic Chemistry & Biochemistry
Czech Academy of Sciences
phone: +420-220 183 540
fax:+420-220 183 292
e-mail:lepsik.uochb.cas.cz
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu