On Wed, Dec 10, 2003, Youyi Peng wrote:
> I am trying to calculate RESP charges for a coordination system which
> consists of a metal ion and several residue fragments. I used antechamber in
> AMBER7.0 to perform this job. After the esp charge calculation with
> Gaussian98, I typed the command: antechamber -i g98.log -fi gout -o
> resp.prepi -fo prepi -c resp -s 2 -nc 2. Then I checked the resp charges in
> th efile resp.prepi and found the charges for the residue fragments are all
> zero. I guess this easy way to calculate RESP charges doesn't work for the
> fragments. What should I do? Do I need to go the traditional way?
> Any suggestions are highly appreciated.
>
Did the Gaussian job complete successfully (check the g98.log file)? If so,
we would need more detailed information to be of much help.
...regards...dac
--
==================================================================
David A. Case | e-mail: case.scripps.edu
Dept. of Molecular Biology, TPC15 | fax: +1-858-784-8896
The Scripps Research Institute | phone: +1-858-784-9768
10550 N. Torrey Pines Rd. | home page:
La Jolla CA 92037 USA | http://www.scripps.edu/case
==================================================================
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Jan 14 2004 - 15:53:06 PST