> We have encountered the very serious problem. It is
> that the water molecules in the middle of MD
> separates. The links and explanations of pictures
> wrote below.
>
> Is a countermeasure in this phenomenon?
Likely you are running a constant volume simulation and the density is not
correct leading to a "vacuum bubble" forming. You need to equilibrate
with constant pressure first to make sure the density is stable/correct
first.
If you were running constant pressure and see this problem, this is a more
serious issue...
\ Thomas E. Cheatham, III (Assistant Professor) College of Pharmacy, Depts of
| Medicinal Chemistry and of Pharmaceutics and Pharmaceutical Chemistry
| Adjunct Asst Prof of Bioengineering; Center for High Performance Computing
| University of Utah, 30 South 2000 East, Skaggs 201, Salt Lake City, UT 84112
|
| tec3.utah.edu (801) 587-9652; FAX: (801) 585-9119
\ BPRP295A / INSCC 418
http://www.chpc.utah.edu/~cheatham
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Nov 12 2003 - 04:53:00 PST