Hi:
I followed the manual (page.78) and created 2 resp files by using
respgen, one is like:
Resp charges for organic molecule
&cntrl
nmol = 1,
ihfree = 1,
ioutopt = 1,
&end
1.0
Resp charges for organic molecule
2 28
6 0
6 0
7 0
6 0
6 0
7 0
6 0
16 0
6 0
16 8
9 0
8 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 0
1 24
1 0
1 0
1 27
The first column lookes like atomic mass. I changed '9' into '30',
because that is a Zn. Then I just follow the example in p.78. But it
seems that in the second 'resp' command line (in the manual), the input
file should be 'sustiva.respin2' instead of 'sustiva.respin1'. Finally,
I got the charges, do you think it is right?
Lishan
On Mon, 2003-09-29 at 12:38, Junmei Wang wrote:
>
>
>
> If you will make force constants 0.0, it doesn't matter what types they
> are. You may just use "1". You may manually revise resp input files by
> yourself. The amber7 version of respgen doesn't read in total charge
> information from ac input files (If I remember correctly). Best
>
> Junmei
> ===============================================================
> Dr. Junmei Wang
> Chemistry & Biophysics
> Encysive Pharmaceuticals
> 7000 Fannin, Houston TX 77030
> Tel: 713-5786649
> Email: jwang.tbc.com
> Homepage: Http://sigyn.compchem.ucsf.edu/members/jmwang/index.html
> ===============================================================
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Mon Sep 29 2003 - 21:53:01 PDT