   4.  RESULTS
-----------------------------------------------------------------
     eedmeth=4: Setting switch to one everywhere
 ---------------------------------------------------
| Local SIZE OF NONBOND LIST =    8193242
| TOTAL SIZE OF NONBOND LIST =    8193242
   NSTEP       ENERGY          RMS            GMAX         NAME   
NUMBER
      1       6.7439E+07     1.7942E+07     1.0385E+09     NZ       2889
 BOND    =      216.5081  ANGLE   =      905.7987  DIHED      =    
2173.1263
 VDWAALS = 67435606.3650  EEL     =    -4909.3228  HBOND      =       
0.0000
 1-4 VDW =     1417.0613  1-4 EEL =     3308.6923  RESTRAINT  =       
0.0000
****************************************
 Frac coord min, max:   0.0619183818  1.05405019
 The system has extended beyond 
     the extent of the virtual box.
 Restarting sander will recalculate
    a new virtual box with 30 Angstroms
    extra on each side, if there is a
    restart file for this configuration.
 EWALD BOMB in subroutine Routine: map_coords (ew_force.f)
 Atom out of bounds. If a restart has been written,
 restarting should resolve the error
****************************************
The vdwaals energy suggests some type of atomic clash, but the error
message about the virtual box suggests that there is a problem in the
size of the receptor.  Which one is it?
Thank you!
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Tue Sep 02 2003 - 22:53:01 PDT