RE: AMBER: SHAKE Problem

From: Richard Smith <dicksmit.umich.edu>
Date: Thu, 7 Aug 2003 10:42:56 -0400

Thank you very much Mr. Case and Mr. Periole,

   Equilibration to the final temperature with constant volume was
successful.

Richard Smith

-----Original Message-----
From: owner-amber.scripps.edu [mailto:owner-amber.scripps.edu] On Behalf
Of David A. Case
Sent: Wednesday, August 06, 2003 5:52 PM
To: amber.scripps.edu
Subject: Re: AMBER: SHAKE Problem

On Wed, Aug 06, 2003, Richard Smith wrote:
>
> I am using sander_classic of AMBER6 to equilibrate a protein in an
> octahedral box of TIP3P water. I am using periodic boundary
conditions
> with constant pressure to increase the temperature from 50 - 310K in
50
> K increments at 10 ps each with a 0.002 ps time step

You can't do this. You need to equilibrate a constant volume to the
desired
temperature, and *then* turn on constant pressure to get the density
adjusted.

It's not clear that this is causing your problem, but it is certainly
worth
a try.

....good luck....dac

-- 
==================================================================
David A. Case                     |  e-mail:      case.scripps.edu
Dept. of Molecular Biology, TPC15 |  fax:          +1-858-784-8896
The Scripps Research Institute    |  phone:        +1-858-784-9768
10550 N. Torrey Pines Rd.         |  home page:                   
La Jolla CA 92037  USA            |    http://www.scripps.edu/case
==================================================================
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Thu Aug 07 2003 - 15:53:01 PDT
Custom Search