Re: topology file in large systems

From: <caldwell.heimdal.compchem.ucsf.edu>
Date: Thu, 17 Apr 2003 15:25:49 -0700 (PDT)

Upgrade to Amber7, it is capable of such big systems.

jim


On Thu, 17 Apr 2003, GUILLERMINA L ESTIU wrote:

> I am having trouble with the topology file for a system that has 36300 atoms
> (before solvating with a water box)
> I am using amber6.
> In the dihedral arrays, the "atom number" (~36300x3) goes to 108900. When the
> third or fourth atoms that define the dihedral are negative, they do not fit
> the reading format (12I6) (rdparam.f)
> I do not know which subroutine generates the topology file. I think that I need
> to set the writing format of KP, LP, KPH and LPH to I7
>
> The following are two lines of the dihedral array of the top files. A negative
> value appears in the second line
> 100938100944100950100953 9100938100944100950100956 9101046101043
> 101049101052 1101046101043-101049101052 2101043101049101055101058
>
> Thanks for your help
> Dr Guillermina Estiu
> Chemistry Department
> Pennsylvania State University
> PA 16802
>

-- 
----------------------------------------------------------------------------
NOTE NEW MAILING ADDRESS & FAX NUMBER:
James W. Caldwell                         (voice) 415-476-8603
Department of Pharmaceutical Chemistry    (fax)   415-514-3866  
UCSF Box 2240                             (email) caldwell.heimdal.ucsf.edu
600 16th Street
University of California
San Francisco, CA 94143-2240
----------------------------------------------------------------------------
Received on Thu Apr 17 2003 - 23:53:01 PDT