Problems during equilibration

From: Pratul Agarwal <pratulka_at_rocketmail.com>
Date: Wed 11 Sep 2002 12:38:36 -0700 (PDT)

I am preparing a protein in solvent box (TIP3P water) for MD simulations. I am
seeing some strange behavior during the equilibration steps. After initial
minimization steps, I am doing short MD runs to rescale the box and remove the
"vacuum bubbles". For this I am first performing a constant volume MD run with
slow heating, which is followed by a constant pressure MD run. After the
constant volume MD run I notice that most of the water molecules gather at the
center of the box with few scattered on the outside. This problem continues
with constant pressure MD and the system looks very inhomogeneous. The before
and after snapshots are available at the following locations:

Before MD : http://linus.ornl.gov/MD/before.gif

After const. Vol. MD : http://linus.ornl.gov/MD/after_const_T.gif
(slow heating to 300K)

After const. Press MD : http://linus.ornl.gov/MD/after_const_P.gif
(const. T = 300K)

If anybody can help me find out where the problem is, I would really appreciate
it. Attached are the input files (more information can be found at :
http://linus.ornl.gov/MD/)

============= mdinp for const. volume MD run =================
 &cntrl
   imin=0, irest=0, ntx=1, nmropt=1,
   ntt=1, tempi=100.0, temp0=300.0, tautp=1.0,
   ntb=1, ntc=1, ntf=1, nsnb=10,
   nstlim=20000, dt=0.001
   ntwe=50, ntpr=25, ntwx=500,
   cut=10.0, ntr=1,
 &end
 &wt
   type='TEMP0', istep1=0, istep2=5000,
                 value1=100.0, value2=300.0,
 &end
 &wt
   type='TEMP0', istep1=5000, istep2=20000,
                 value1=300.0, value2=300.0,
 &end
 &wt
   type='END',
 &end
 &rst
   iat=0,
 &end
Apply restraints to the solute atoms
 500.0
RES 1 168
END
END
=============================================================

================== mdinp for const. volume MD run ===========
 &cntrl
   imin=0, irest=0, ntx=5,
   ntt=1, tempi=300.0 temp0=300.0, tautp=1.0,
   ntb=2, ntp=1, taup=1.0,
   ntc=1, ntf=1, nsnb=10,
   nstlim=30000, dt=0.001
   ntwe=50, ntpr=25, ntwx=500,
   cut=10.0, ntr=1,
 &end
Apply restraints to the solute atoms
 500.0
RES 1 168
END
END
=====================================================================

__________________________________________________
Yahoo! - We Remember
9-11: A tribute to the more than 3,000 lives lost
http://dir.remember.yahoo.com/tribute
Received on Wed Sep 11 2002 - 12:38:36 PDT