Ewald Bomb

From: Luis Gracia <lgracia2_at_alumni.unav.es>
Date: Mon 02 Oct 2000 17:30:10 +0100

Hi everybody,

I have got an error message while running a sander MD with PME and NPT.
It appears just in the first cycle. It is a restart run from a previous
sander MD.
It says:

--------------------
EWALD BOMB in subroutine ewald_list
 volume of ucell too big!!
a regular restart should fix things
--------------------

I tried too just run it again, but it failed (I used the -O sander
option). Another option was to use the restrt file produced, but it is
still empty. Any idea what is happening and how can it be solved?

I attach here the .in file, for information:

--------------------
p50.md5.in
 &cntrl
  timlim = 999999, imin = 0,

  ntx = 7, irest = 1,

  ntxo = 1, ntpr = 100, ntwr = 100, iwrap = 0,
  ntwx = 100, ntwv = 0, ntwe = 0,
  ioutfm = 0, ntwprt =0,
  
  ntf = 1, ntb = 2, dielc = 1.0, cut = 9.0, igb = 0,
  scnb = 2, scee = 1.2,

  ipol = 0,

  ibelly = 0, ntr = 1,

  maxcyc = 99999, ncyc = 500, ntmin = 1,
  dx0 = 0.01, dxm = 0.5, drms = 0.25,

  nstlim = 30000, ndfmin = 0, ntcm = 0, nscm = 0, t = 0.0, dt = 0.001,

  temp0 = 298, tempi = 298, ntt = 1, dtemp = 0.0, tautp = 2.0, vlimit =
0.0,

  ntp = 1, pres0 = 1.0, taup = 0.2, npscal = 0,

  ntc = 1, tol = 0.00025
 &end
 &ewald
 &end
peptid
 5.0
RES 1 193
END
END
--------------------

Thanks in advance,

Luis Gracia

-- 