Re: [AMBER] CPPTRAJ grid output units

From: Daniel Roe via AMBER <amber.ambermd.org>
Date: Sat, 4 Jan 2025 12:46:27 -0500

Sorry for the delay replying!

Yes, by default the ‘grid’ action just increments a voxel every time a
selected atom falls within that voxel. So you have it correct!

-Dan

On Thu, Dec 26, 2024 at 3:47 PM Cianna Calia via AMBER <amber.ambermd.org>
wrote:

> Dear Amber community,
>
> I have been using the following cpptraj input to obtain dx files for
> visualizing the spatial distribution of water around a protein:
>
> parm ../../production/100ns_1/FFFF_TTr1.prmtop
> trajin ../../production/100ns_1/FFFF_TTr1_100ns_1.nc
> autoimage anchor :27-29,47-49,67-69,87-89.CA,C,O,N origin
> principal :27-29,47-49,67-69,87-89.CA,C,O,N dorotation
> rms first :27-29,47-49,67-69,87-89.CA,C,O,N
> average avg.pdb :1-120
> grid FFFF_TTr1_100ns_1_242K_sdfOw-v1.dx 24 0.5 40 0.5 54 0.5 (:WAT.O)
> run
>
> Just want to check if I'm understanding the output correctly: The number
> for each voxel is the number of frames in which that voxel was occupied by
> a water oxygen, right?
>
> Thanks!
> Cianna
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Jan 04 2025 - 10:00:02 PST