Re: [AMBER] imaging membrane system

From: Stéphane Téletchéa via AMBER <amber.ambermd.org>
Date: Mon, 9 Dec 2024 10:17:39 +0100

Dear all,

Back on this, I think I found a more robust solution.

While looking at the "autoimage" function, it turns out that it took my
proteins (I have two) + some lipids (like 15 additional ones).

Le 10/03/2024 à 17:46, Daniel Roe via AMBER a écrit :
> Hi,
>
> Try using the moveanchor keyword, which when determining fixed positions
> uses the previous molecule as an anchor. It’s a bit of a hack but I’ve had
> it work well with membrane systems.
>
> -Dan

Instead of using autoimage (which was nearly fine to me), I used the
proteins residues + all the lipids involved in the upper leaflet:

center ":1-569" mass origin
image origin center familiar
center ':PA,PC,OL'

This allows to produce a nice imaged system with all the lipids in the
correct box, and the protein centered mostly
in the middle of the membrane, as expected from the starting coordinates.

HTH,

Stéphane

-- 