Re: [AMBER] Quick QM/MM fails with GPUs but not with CPUs

From: Goetz, Andreas via AMBER <amber.ambermd.org>
Date: Tue, 5 Mar 2024 21:44:15 +0000

Hi Fernando,

The QUICK version that ships with AmberTools 23 does not support f functions. 6-31G(d), cc-pVTZ and def2-SVPD basis sets contain f functions for Cu. The error message that should be generated has inadvertently been deactivated. You would have to use a basis set that does not contain f functions.

F functions will be supported with the next release, QUICK 24.03 and AmberTools 24. Initially only for closed shells (e.g. Cu+ but not Cu2+) on GPUs, closed and open shells on CPUs.

All the best,
Andy


Dr. Andreas W. Goetz
Associate Research Scientist
San Diego Supercomputer Center
Tel: +1-858-822-4771
Email: agoetz.sdsc.edu
Web: www.awgoetz.de

On Mar 5, 2024, at 8:58 PM, Montalvillo, Fernando via AMBER <amber.ambermd.org> wrote:

Hi,

I am trying to run some QM/MM calculations with Sander.quick.cuda, but the energy minimization of the QM region is being troublesome.

I did a MM minimization of the lipids and solvent molecules of my system (restraining protein atoms and Cu ion) due to lipids always having very bad clashes.

The next minimization is already with QM/MM. I have used multiple basis set with HF, B3LYP and O3LYP and the results are as follows:


Regardless of HF or the other DFT methods I have used, QM energy explodes when using GPUs and higher accuracy basis sets suchs as 6-31G(d), cc-pVDZ, def2-SVPD. But if I use lower accuracy methods such as 6-31G or 3-21G, it can run on GPUs and energies look fine (QM atoms don't seem to be manipulated during the minimization only MM atoms).


Using CPUs, I can run with the more accurate basis sets, but it is slow, and the QM atoms also don't seem to be manipulated during the minimization. So, when I use the restart file to continue next step with GPUs (maybe heating or another minimization), the energies explode again despite using the same method and basis set that had been used in the minimization with CPUs.

Can you point at what I am doing wrong or what should I check? This is my first QM/MM simulation, so I don't know what I am doing.

Thanks for your invaluable help and time.

Fernando
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
https://urldefense.com/v3/__http://lists.ambermd.org/mailman/listinfo/amber__;!!Mih3wA!GOclVpA2BKKnXDQFyIBlRRVPGA4eH66BOYV4wji5yPhpoZlwiJtuaiiZmnya62nsM1iekNbT8PeTQw$

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Mar 05 2024 - 14:00:02 PST