[AMBER] QM+cutoff larger than box error -Qm/Mm simulation

From: keerthi vaasan <keerthiiitkgp2000.gmail.com>
Date: Sat, 16 Apr 2022 18:11:32 +0530

Hello amber users ,

I have started to work on QM/MM simulation with DFTB theory. While running
the script for QM/MM I'm getting the following error where it shows
qm+cutoff larger than the box . I have tried to resolve this by lowering
the two cutoff values to 8 angstroms but still, the error persists. Please
help me to solve this problem.Thank you in advance

QMMM: ADJUSTING CHARGES
QMMM: ----------------------------------------------------------------------
QMMM: adjust_q = 2
QMMM: Uniformly adjusting the charge of MM atoms to conserve total charge.
QMMM: qm_charge = 0
QMMM: QM atom RESP charge sum (inc MM link) = 1.639
QMMM: Adjusting each MM atom resp charge by = 0.000
QMMM: Sum of MM + QM region is now = 0.000
QMMM: ----------------------------------------------------------------------
| # of SOLUTE degrees of freedom (RNDFP): 159126.
| # of SOLVENT degrees of freedom (RNDFS): 0.
| QMSHAKE_NOSHAKEMASK_OVERLAP = 0
| NDFMIN = 159126. NUM_NOSHAKE = 0 CORRECTED RNDFP = 159126.
| TOTAL # of degrees of freedom (RNDF) = 159126.
 ---------------------------------------------------
 APPROXIMATING switch and d/dx switch using CUBIC SPLINE INTERPOLATION
 using 5000.0 points per unit in tabled values
 TESTING RELATIVE ERROR over r ranging from 0.0 to cutoff
| CHECK switch(x): max rel err = 0.2738E-14 at 2.422500
| CHECK d/dx switch(x): max rel err = 0.8332E-11 at 2.782960
 ---------------------------------------------------
| Local SIZE OF NONBOND LIST = 183976
| TOTAL SIZE OF NONBOND LIST = 11415129
  ****************************************************
  ERROR: QM region + cutoff larger than box dimension:
  QM-MM Cutoff = 8.0000
   Coord Lower Upper Size Radius of largest sphere inside unit cell
     X -47.333 47.290 94.623 37.767
     Y -45.339 45.595 90.933 37.767
     Z -50.808 50.327 101.135 37.767
  ****************************************************
 SANDER BOMB in subroutine QM_CHECK_PERIODIC<qm_mm.f>
 QM region + cutoff larger than box
 cannot continue, need larger box.

Thanking You,


Warm Regards,


----------------------------------------------------------------------------------------------



M Keerthi Vaasan

Final Year Undergraduate

Department of Chemistry

IIT Kharagpur.

Contact: (+91) - 7384429604

Skype

----------------------------------------------------------------------------------------------






_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Apr 16 2022 - 06:00:02 PDT