On Thu, Sep 16, 2021, Matthew Guberman-Pfeffer wrote:
>
>I noticed that the surface charge I obtain with he pbsa module is, for
>example, 28.5572e. Is the deviation from 29e, which is what I expect
>an issue with numerical accuracy settings, or is there something more
>fundamental at work that I don’t know.
>
>The molecular system I gave to PBSA is just the protein (explicit water and
>ions stripped off) and has a net charge of -29e.
This is exactly what you should expect. For a finite exterior dielectric,
the induced surface charges do not fully screen the molecular charge.
The result is that a test charge outside the molecule would still feel a
(screened) electrostatic interaction with the molecule plus its surface
charges.
The amount by which the surface charge differ from the molecule charge is a
factor of (1 - 1/epsilon), where epsilon is the exterior dieletric. This
matches you result pretty closely.
...dac