[AMBER] Restart

From: Henry Green <henrygreen47k.gmail.com>
Date: Mon, 6 Sep 2021 11:22:20 +0530

Ross Walker Sir had advised me to run the md again with the restraints
turned off in the md input files. However the problem of Temperature fall
has prevailed. Any advice is much appreciated.

Thanking you,
Diganta

On Mon, 6 Sept 2021 at 11:16, Henry Green <henrygreen47k.gmail.com> wrote:

>
>
> On Mon, 6 Sept 2021 at 11:10, Henry Green <henrygreen47k.gmail.com> wrote:
>
>>
>>
>> On Mon, 6 Sept 2021 at 11:05, Henry Green <henrygreen47k.gmail.com>
>> wrote:
>>
>>> Respected Sir/Madam,
>>>
>>> My name is Diganta Dasgupta and I am a student in JNU, India. I have
>>> recently started to learn MD using AMBER. I am writing this mail to inform
>>> you of an error which I have encountered while doing so.
>>> I have started using AMBER 18 and was trying out the Tutorials
>>> provided at the AMBER website. In the Section 5 of Tutorial no. (5.2)
>>> titled "Simulating a DNA polyA-polyT Decamer" provided by Ross Walker Sir,
>>> which involves simulating the Decamer system in explicit solvent, it was
>>> mentioned that one should heat the system (to 300 K), after minimization
>>> (2-step), over a run of 20 ps in the NVT ensemble (using SHAKE on the
>>> Hydrogens and a weak restraint on the DNA), followed by a moderately long
>>> MD run in the NPT for Equilibration ( at 300 K). The .ncrst from
>>> minimization (only the coordinates) was to be used as the restart file for
>>> the heating step and the .ncrst from the heating (coordinates and
>>> velocities) was to be used as the restart for the Equilibration. Upon
>>> running the job as instructed and plotting the summary files on GNUplot, it
>>> was observed that initially the temperature rose as expected to 300 K
>>> within the 20 ps of heating simulation. However at the point of restart
>>> (i.e. right after the 20 ps mark) there is a sharp drop in Temperature by
>>> approx. 100 K and thereafter it again rose back to 300 K and stayed there
>>> the rest of the way.
>>> To further investigate this issue I ran the heating and
>>> Equilibration steps several times over with different break and restarts
>>> points and made the following observations :
>>>
>>> (i) The ensemble (NPT or NVT) did not matter and at each restart (
>>> irrespective of how many ps apart the restarts were done) there was a
>>> decrease in the temperature. I have tried breaking the 20 ps heating step
>>> into 2-3 steps and even in this I have observed the decrease at the restart
>>> points.
>>>
>>> (ii) The effect of this Temperature fall was observed in the other data
>>> like the Energy (Total, Potential and Kinetic - instead of reaching
>>> equilibrium values and fluctuating around the equilibrium values,these too
>>> decrease at the restart points),Pressure and Density.
>>>
>>> (iii) The .out file of the previous run shows final Temperature = 300 K
>>> and some energy values; however the next run's .out starts with different
>>> restart Temperature and energy values. This is observed at each break.
>>>
>>> From my Professor and Seniors I have come to know this issue was
>>> previously encountered on AMBER 18 but was not observed on running the same
>>> on AMBER 14.
>>> I understand that the Tutorial was made for the previous versions of
>>> AMBER and am confused regarding the cause of this error. Any guidance
>>> regarding this is much appreciated.
>>> I have herein attached the files for my last attempt at the
>>> simulation (this involves only the heating step; I have broken the heating
>>> step into 3 parts : 1st is a 10 ps run with a 10 kcal/mol.A restraint on
>>> the DNA, 2nd a 6 ps run with a 5 kcal/mol.A restraint on DNA and the 3rd is
>>> a 4 ps run with 3 kcal/mol.A on the DNA.
>>>
>>> Thanking you,
>>> Diganta Dasgupta
>>>
>>>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Sep 05 2021 - 23:00:03 PDT
Custom Search