Look for things that a different with the ligand that fails. Run a
simulation that stops right before the crash, and examine the structure that
you have, both visually, and with the "checkstructure" action of cpptraj.
>> Also, be sure that you have applied all updates: in particular, not
>> applying
>> update.8 may lead to instabilities if you are using the ff19SB force field.
I don't remember that you have answered this question, or even indicated what
force fields you are using.
....dac