Hi Dr. Giambasu,
Thank you so much for your kind advice. It was really helpful! And I was able to get smaller blobs using the higher threshold values as you suggested.
I built the protein from a crystal structure, so I align the positions given from MoFT with the crystal structure. I am able to trim down a lot of points when threshold varies from 0.1 to 0.3, and the alignment is still great with the crystallographically-resolved water molecules.
I have two more questions about choosing a threshold value and about the occupancy values:
(1) As the threshold increases, more and more points are eliminated, because the Laplacian at these positions is less negative than the reference Laplacian (=threshold*min(Laplacian)). Is it right to think that the eliminated positions are likely the false positives where a solvent molecule should not be placed at?
(2) For the occupancy values, am I right in thinking that one can average the occupancy values by volume of the blob, or is there some way to get the individual occupancy value for each position in a blob?
Thank you again for your time and kind help.
Thanks,
Amy H
--
Amy He
Chemistry Graduate Teaching Assistant
Hadad Research Group
Ohio State University
he.1768.osu.edu
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Mar 24 2021 - 22:00:02 PDT