Hello Carlos and Daniel
I've provided editing permissions should you want to provide notes or files though the off-list sharing option.
Some thoughts
Dan
I seem to remember this causing issues before. I do get the top-down/bottom-up priorities mixed up quite often. I will definitely give this a try as the OPC only system works quite well. This is still surprising to be, with the split of parameters into "protein" and "water" it is somewhat confusing if there are deviating parameters in the "protein" part affecting the "water" part. Still, I do not have enough insight to make any judgment. This needs to be corrected regardless if this is causing the issue or not. Thank you very much
Carlos
1) Yes, the peptide is the "raw" sequence from leap as supplied without any relaxation/minimization. This is obviously something that I need to look into as soon as I get the system working. However, at the moment I am more concerned about the water molecules being "frozen" during the dynamic part of the simulation.
2) Yes, as this was to test if I could produce usable input I wanted the packing to finish ASAP and left a lot of space in the system. I still find it surprising as the OPC system without the peptide provided usable data with the "process_m*.perl" scritps and equilibrated to a density around 0.99 g/ml faster than the other water models. system with the peptide, where water basically does not move at all during any stage of simulation.
As of now I think that Dan might be on to something, unless your suggestion to check available patches would resolve the problem Carlos.
Thank you both for your time and efforts, much appreciated
Best regards
// Gustaf
________________________________
Från: Carlos Simmerling <carlos.simmerling.gmail.com>
Skickat: den 23 oktober 2020 16:34:22
Till: AMBER Mailing List
Ämne: Re: [AMBER] ff19SB and OPC, process_(min/md)out.perl and LEaP
to add more info to Dan's analysis, I noticed that your input coordinates
have some concerns.
1) there are very close contacts in your peptide (as low as 0.6 angstrom)
that become a challenge to minimize once in water (since the water won't
move far in minimization)
2) the initial density is very, very low (0.3) which may lead to the
problems you observed in getting the density to equilibrate. It can be
done, but will likely need different inputs than what are typically used
with better solvent positioning. Usually people solvate in leap using a
pre-equilibrated water box and start with a better density.
On Fri, Oct 23, 2020 at 10:30 AM Daniel Roe <daniel.r.roe.gmail.com> wrote:
> Hi Gustaf, thanks for the files.
>
> So I haven't run anything yet but I think I've spotted an issue right
> off the bat. In your original leap script you have the following:
>
> ```
> source leaprc.water.opc
> source leaprc.protein.ff19SB
> WAT = OPC
> ```
>
> This is problematic because it allows the 19SB frcmod to overwrite
> parameters set by the OPC frcmod. The manual gives an example of
> loading different parameter files at the beginning of section 3
> (Molecular mechanics force fields) that gives a typical load order,
> but I don't think it emphasizes how much the order can matter - that's
> something that needs to be fixed.
>
> Anyway, if I reorder the parameter files so the protein FF comes first
> and the solvent model last, like so:
>
> ```
> source leaprc.protein.ff19SB
> source leaprc.water.opc
> go = loadpdb ../ff19SB_opc/waterPeptBox.pdb
> setbox go vdw
> saveamberparm go test.waterPeptBox-opc.prmtop test.waterPeptBox-opc.inpcrd
> quit
> ```
>
> And then compare the two topologies using the 'comparetop' command from
> cpptraj:
>
> ```
> parm waterPeptBox-opc.prmtop
> parm test.waterPeptBox-opc.prmtop
> comparetop parmindex 0 parmindex 1 out parm.diff
> ```
>
> I can see that in my "test" topology (denoted by '>') the correct OPC
> water parameters are assigned compared to your original topology, e.g.
>
> ```
> # LJ params
> < OW Rmin= 1.7683 Eps= 0.152
> > OW Rmin= 1.77717 Eps= 0.212801
> ```
>
> I sent the full diff and topology/coordintae files to you off-list.
> Because the parameters assigned are different, the output coordinates
> end up being a little different as well. I still need to run tests on
> the "new" topology, but I suspect this may be the problem right here.
> Let me know if this makes sense and/or if you have more questions.
>
> -Dan
>
> On Fri, Oct 23, 2020 at 7:28 AM Daniel Roe <daniel.r.roe.gmail.com> wrote:
> >
> > If you’d like, send me off-list your topology and the problematic
> coordinates and I can check it out and try to reproduce the bad behavior,
> and hopefully smoke out any bugs.
> >
> > -Dan
> >
> > On Fri, Oct 23, 2020 at 7:13 AM Gustaf Olsson <gustaf.olsson.lnu.se>
> wrote:
> >>
> >> Thank you very much for the tips, I will look at them carefully as soon
> as I have time. I am sure I will have use for these at some point.
> >>
> >> Just to avoid confusion. This is a very small system with an initially
> linear, capped hexapeptide. I am doing energy minimisation, temperature
> equilibration and pressure equilibration with no restraints. I am aware of
> the basic idea for proteins/membranes, alternating restraining the movement
> of some structures while letting others move and so forth. My reservation
> is that this only system seems to have everything constrained though no
> restraints have been used whatsoever. The other systems using ff14SB with
> SPCE/TIP3P and the plain OPC water system are equilibrated using identical
> input so unless there is some input option not compatible with ff19SB, then
> the protocol should not be the cause of the observed behaviour.
> >>
> >> If the system did not equilibrate properly, that would be “fine”.
> Though I am getting nothing in the “process_m*.perl” scripts output
> regarding energy minimisation or pressure equilibration. Visually, there is
> no “diffusion”/spreading of waters. Everything seems to be “locked” in
> place, no water is displaying any expected degree of rotation or movement.
> The system is basically incompressible.
> >>
> >> I could try ff14SB-OPC and ff19SB-tip3p/spce to see if anything changes
> though was hoping that someone would notice some obvious mistake.
> >>
> >> Thank you again for suggestions and tips, it is greatly appreciated.
> >>
> >> I’ll keep trying
> >> Best regards
> >> // Gustaf
> >>
> >>
> >> > On 23 Oct 2020, at 11:36, Daniel Roe <daniel.r.roe.gmail.com> wrote:
> >> >
> >> > Hi Gustaf,
> >> >
> >> > I’m not sure what equilibration protocol you’re using, but the one I
> use
> >> > generally does the trick, detailed here:
> >> > https://aip.scitation.org/doi/abs/10.1063/5.0013849
> >> >
> >> > I also have a script that implements it for amber (it’s a bit rough
> around
> >> > the edges so use with care):
> >> > https://github.com/drroe/AmberMdPrep
> >> >
> >> > Hopefully it is helpful.
> >> >
> >> > -Dan
> >> >
> >> > On Fri, Oct 23, 2020 at 5:26 AM Gustaf Olsson <gustaf.olsson.lnu.se>
> wrote:
> >> >
> >> >> I am experiencing some other problem, it seems that the OPC water
> >> >> simulation works as intended though a box with a capped hexapeptide
> and a
> >> >> Cl- ion does not.
> >> >>
> >> >> I have run 6 short simulations 3 with only water (OPC, SPCE and
> TIP3P) as
> >> >> well as 3 with the same water models as well as a hexapeptide and a
> >> >> chloride ion (FF14SP-SPCE, FF14SB-TIP3P and FF19SB-OPC).
> >> >>
> >> >> All systems with only water equilibrates nicely inside the
> timeframe. The
> >> >> pressure equilibration of OPC water is finished faster then the SPCE
> and
> >> >> TIP3P models and all simulation produce usable plots with the
> >> >> “process_m*.perl” scripts. Everything looks fine.
> >> >>
> >> >> The FF19SB-OPC system does NOT behave as intended. I can keep
> hammering
> >> >> this system with higher pressure and shorter taup though looking at
> the
> >> >> simulation, it seems like I am trying to equilibrate a block of ice
> with
> >> >> air trapped inside: https://gifyu.com/image/865p (Do note that I
> have NOT
> >> >> autoimaged with CPPTRAJ, the restricted motion of the water prevents
> >> >> changing the shape).
> >> >>
> >> >> Running only OPC water works just fine, so it seems that it is the
> FF19SB
> >> >> part which does not work as intended. For some reason, the entire
> system
> >> >> appears to be suffering from some motion restriction though I have
> >> >> implemented none. I have tried to see if the manual contained any
> >> >> information regarding particular options for input files or similar
> but did
> >> >> not find anything.
> >> >>
> >> >> I used the same input for all simulations:
> >> >>
> >> >> Energy minimization, 5000 steps SD then 5000 CG
> >> >> &cntrl
> >> >> imin=1,
> >> >> maxcyc=10000,
> >> >> ncyc=5000,
> >> >> ntb=1,
> >> >> cut=9.0,
> >> >> /
> >> >>
> >> >> 125 ps to constant T
> >> >> &cntrl
> >> >> ig =-1,
> >> >> imin = 0,
> >> >> iwrap = 0,
> >> >> irest = 0,
> >> >> ntx = 1,
> >> >> ntb = 1,
> >> >> cut = 9.0,
> >> >> ntc = 2,
> >> >> ntf = 2,
> >> >> tempi = 0.0,
> >> >> temp0 = 293.15,
> >> >> ntt = 3,
> >> >> gamma_ln = 1.0,
> >> >> nstlim = 62500, dt = 0.002,
> >> >> ntpr = 1000, ntwx = 1000, ntwr = 2000
> >> >> /
> >> >>
> >> >> Constant T, pressure eq: 500 ps MD
> >> >> &cntrl
> >> >> ig =-1,
> >> >> imin = 0,
> >> >> iwrap = 0,
> >> >> irest = 1,
> >> >> ntx = 5,
> >> >> ntb = 2,
> >> >> pres0 = 1,
> >> >> ntp = 1,
> >> >> barostat = 1,
> >> >> taup = 2.0,
> >> >> cut = 9.0,
> >> >> ntc = 2,
> >> >> ntf = 2,
> >> >> tempi = 293.15,
> >> >> temp0 = 293.15,
> >> >> ntt = 3,
> >> >> gamma_ln = 1.0,
> >> >> nstlim = 250000, dt = 0.002,
> >> >> ntpr = 1000, ntwx = 1000, ntwr = 2000
> >> >> /
> >> >>
> >> >> All the intended output files are produced and seemingly (except for
> the
> >> >> restricted motion) looks normal and reads just fine in cpptraj and
> vmd.
> >> >>
> >> >> Any ideas regarding what I am doing wrong?
> >> >>
> >> >> Best regards
> >> >> // Gustaf
> >> >>
> >> >>
> >> >>> On 22 Oct 2020, at 15:06, Carlos Simmerling <
> carlos.simmerling.gmail.com>
> >> >> wrote:
> >> >>>
> >> >>> Dave - no I haven't tried that during equilibration, since tighter
> >> >> coupling
> >> >>> fixes it I just made it part of our equilibration protocol long ago
> and
> >> >>> moved on. I'll try that since I have a sample setup with a bubble
> and see
> >> >>> if it works better.
> >> >>> carlos
> >> >>>
> >> >>> On Thu, Oct 22, 2020 at 8:48 AM David A Case <
> david.case.rutgers.edu>
> >> >> wrote:
> >> >>>
> >> >>>> On Wed, Oct 21, 2020, Carlos Simmerling wrote:
> >> >>>>
> >> >>>>> what is your pressure coupling constant? I often get vacuum
> bubbles
> >> >> unless
> >> >>>>> I include a step in my equilibration with tight coupling, taup
> around
> >> >> 0.1
> >> >>>>> or smaller.
> >> >>>>
> >> >>>> Carlos: have you ever tried barostat=2? It would be interesting
> to know
> >> >>>> if that makes a difference. Also, what is your starting density?
> If
> >> >>>> you use a closeness parameter of 0.7--0.8 (in solvateBox or
> solvateOct),
> >> >>>> you'll get a higher starting density, which might(?) reduce the
> tendency
> >> >>>> to get bubbles.
> >> >>>>
> >> >>>> ....dac
> >> >>>>
> >> >>>>
> >> >>>> _______________________________________________
> >> >>>> AMBER mailing list
> >> >>>> AMBER.ambermd.org
> >> >>>> http://lists.ambermd.org/mailman/listinfo/amber
> >> >>>>
> >> >>> _______________________________________________
> >> >>> AMBER mailing list
> >> >>> AMBER.ambermd.org
> >> >>> http://lists.ambermd.org/mailman/listinfo/amber
> >> >>
> >> >> _______________________________________________
> >> >> AMBER mailing list
> >> >> AMBER.ambermd.org
> >> >> http://lists.ambermd.org/mailman/listinfo/amber
> >> >>
> >> > _______________________________________________
> >> > AMBER mailing list
> >> > AMBER.ambermd.org
> >> > http://lists.ambermd.org/mailman/listinfo/amber
> >>
> >> _______________________________________________
> >> AMBER mailing list
> >> AMBER.ambermd.org
> >> http://lists.ambermd.org/mailman/listinfo/amber
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Oct 23 2020 - 10:30:02 PDT