Re: [AMBER] Error adding OH⁻ ions in a simulation box

From: Lucas Bandeira <bandeiralucas97.gmail.com>
Date: Tue, 22 Oct 2019 18:09:50 -0300

Yes! It worked properly!

Thank you very much for your help!

Lucas Bandeira

On Tue, Oct 22, 2019 at 9:42 AM David A Case <david.case.rutgers.edu> wrote:

> On Mon, Oct 21, 2019, Lucas Bandeira wrote:
> >
> >I'm trying to add NaOH in a water box. What I did was: I removed one
> >hydrogen from the water pdb and used pdb4amber to "correct" it. I've also
> >used antechamber to create OH⁻ óns parameters. However, I have the
> >following warnings and errors:
> >
> >>>Unknown residue: OH number: 2676 type: Nonterminal
>
> You are loading the PDB file before you have loaded the mol2 file that
> defines the OH unit. Try putting the loadPdb command right before the
> saveAmberParm command.
>
> ...dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Oct 22 2019 - 14:30:02 PDT