Hi,
I'm not able to reproduce the behavior that you see. I'm using the
same input but likely a different system (GB3 solvated in 4473 SPCE
waters). Can you post more details about the system you are simulating
and how you are calculating the diffusion (for which molecule(s), what
program/input, etc).
-Dan
On Mon, Feb 11, 2019 at 9:57 PM Abdullah Bin Faheem
<abdullahbinfaheem.hotmail.com> wrote:
>
> I'm using amber 12.0, where the default value for the seed is 71277, nevertheless I observed the same behaviour even with the "ig=-1" setting, i.e. different msd slopes.
>
> Regards,
> Abdullah
>
> ________________________________
> From: David A Case <david.case.rutgers.edu>
> Sent: Monday, February 11, 2019 10:23 PM
> To: AMBER Mailing List
> Subject: Re: [AMBER] Behavior of MSD at different collision frequency values
>
> On Mon, Feb 11, 2019, Abdullah Bin Faheem wrote:
> >
> >I would like to inquire about some behaviour observed while running
> >NPT simulations on electrolyte systems by both using single long
> >trajectoriesor dividing the long trajectory into numerous smaller runs
> >(for e.g. one 1.5 ns run or three 500 ps runs). It seems that at each
> >restart the MSD curve shows a "bump", where the MSD curve drops in slope
> >at the end. Reducing the collision frequency (gamma_ln) from 5 ps to
> >1 ps (for Langevin dynamics at ntt=3), seems to give more similar MSD
> >curves however the drop in slope exists. This drop only exists for the
> >aforementioned smaller runs. I have attached both MSD's for reference and
> >the input file is as follows:
> >
> >NPT ensemble simulation with temperature scaling
> > &cntrl
> > imin = 0, irest = 1, ntx = 5, ntpr = 500, ntave = 1000,
> > ntwr = 500, ntwx = 100, ntwe = 50, ntf = 2, ntc = 2, ntb = 2,
> > cut = 12.0, nsnb = 10, nstlim = 500000, dt = 0.001,
> > tempi = 298.0, temp0 = 298.0, ntt = 3, tautp = 1.0,
> > ntp = 1, pres0 = 1.0, taup = 1.0, ioutfm=1, gamma_ln=5,
> > &end
>
> This has the flavor problems that arise in Langevin dynamics when the same
> random number sequence is re-used for multiple runs. What version of
> Amber are you using? The current default is (I think) ig=-1, which forces
> a new random number seed for each segment. But earlier versions had a
> default with a fixed seed. Check your outputs to see what seed is being
> used, and make sure it is different for each run.
>
> This may not be the problem, but it's simple to check. If you are
> re-using the same seed, add "ig=-1" to your input files.
>
> ...dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Feb 15 2019 - 05:30:02 PST